ÖloFEscence Liquid elements have been design for two phase liquid and to address the toughest applications in the Oil & Gas industry. We only use the highest quality materials and the most robust designs. We handle a wide variety of filters elements with different construction materials, couplings and extras so your process will be maintained in the quality standards you are accustomed.

Features

  • High effective filtering area, low initial differential pressure and excellent retention capacity of contaminants.
  • Nominal rated filter.
  • Increased overall process performance.
  • Decreased Downtime.
  • Lower maintenance costs.
  • Wide chemical compatibility.
  • Internal central support, unique in high flow filters, for a great resistance in high pressures.
  • Low maintenance frequency and less number of cartridges needed.
  • Available in ratings from 1 to 50 microns depending on the filter selected
  • Reduces drastically the space normally used for filtering systems.
ÖlofEscense – S Series / Pleated Coalescers

Pleated media of treated silicone impregnated cellulose to produce hydrophobic media that repels water while allowing hydrocarbons to pass trough. Due to the filtration level achieved in the coalescence stage this filters rarely foul with solids and typically require replacement only every second or third coalesce change to a maximum service life of one year.

Specifications

Clean ΔP<1 PSID
Final ΔP8 PSID
Collapse ΔP75 PSID
Max Temperature300ºF
Micron Rating5 μm
pH Range5-9
MediaSilicone Impregnated Cellulose
Standard HardwareTin Plated Steel
GasketsBuna, EPR, Viton

Standard Configurations

Model (Dimensional code)Configuration
S-116”OD x 3.5”ID x 11.25”L
S-136”OD x 3.5”ID x 14.50”L
S-156”OD x 3.5”ID x 16.50”L
S-166”OD x 3.5”ID x 14.25”L
S-186”OD x 3.5”ID x 28.25”L
S-22J 6”OD x 3.5”ID x 22.25”L
ÖlofEscense – ST Series / Teflon Coalescers

Industrial Separator Elements constructed of Teflon® coated stainless steel screen. Similar to the S Series, ST hydrophobic Teflon media repels water while allowing hydrocarbons to pass through. Due to the filtration level achieved in the coalescer stage, ST elements also rarely foul with solid contaminants. ST elements are highly compatible in most applications and can withstand a wide pH.

Specifications

Clean ΔP <1 PSID
Final ΔP8 PSID
Collapse ΔP75 PSID
Max Temperature300ºF
Micron Rating200 mesh
pH Range1-14
MediaTeflon Coated Stainless Steel
Standard HardwareAluminum
GasketsBuna, EPR, Viton

Standard Configurations

Model (Dimens. code)Configuration
ST-6116”OD x 3.5”ID x 11.25”L
ST-6146”OD x 3.5”ID x 14.50”L
ST-6226”OD x 3.5”ID x 22.50”L
ST-6336”OD x 3.5”ID x 33.25”L
ST-6366”OD x 3.5”ID x 36.00”L
ST-6446”OD x 3.5”ID x 44.00”L

Ordering Guide

TypeDimensionsMicron RatingOptionsConfiguration
S - Treated Cellulose SeparatorDimensional CodeMay not be used (S model 5μm) Special ConstructionNo Symbol = DOE
ST - Teflon® Coated SS SeparatorDimensional CodeMay not be used (ST model 200 mesh)Special ConstructionTB = Threated Base
ÖlofEscense – Wafer Pack Series

Liquid Coalescing Wafer Packs are designed in various materials and media densities specifically engineered for the separation of immiscible liquids. Through controlled fiber sizes and carefully distributed media densities, ÖlofEscense wafer packs provide maximum coalescing surface area to ensure the optimal fluid contact time prior to gravitational phase separation of coalesced fluids.

Specifications

MediaPFGSSEX
Solids Removal5μm5μm5μm
Initial ΔP< 2 PSID< 1 PSID< 1 PSID
Final ΔP8 PSID8 PSID8 PSID
Maximum Temperature300 °C600 °C250 °C
Effluent Residual15 - 20 ppm20 ppm35 - 50 ppm
ÖlofEscense – C Series / Cartridge Phase Coalescer

Liquid Phase Coalescer Elements are designed to coalesce two immiscible liquid phases within a stream to aid separation. In addition to liquid coalescing, C Series cartridges are also highly efficient particulate filters. To safe guard against solids, C elements should always be protected by a pre-filter. In installations where no pre-filter exists, the CP Series uses an additional pleated section on the upstream side of the coalescing media to extend the effective operating life and protect coalescing media.

Specifications

Clean ΔP<2 PSID
Final ΔP8 PSID
Collapse ΔP<75 PSID
Max Temperature300ºF
Micron Rating0.5, 1, 5, 10, 15
pH Range5 – 9
MediaGlass Fiber
Standard HardwareTeen plated steel
GasketsBuna, EPR, Viton

Standard Configurations

Dimensional CodeFlow directionDimensionsNet Surface AreaEffluent Residual
C-10Inside to outside6”OD x 3.5”ID x 11.25”L0.94 ft²10 ppm
C-12Inside to outside6”OD x 3.5”ID x 22.25”L1.85 ft²10 ppm
C-14Inside to outside6”OD x 3.5”ID x 33.25”L2.77 ft²10 ppm
C-16Inside to outside6”OD x 3.5”ID x 14.25”L1.19 ft²10 ppm
C-18Inside to outside6”OD x 3.5”ID x 28.25”L2.35 ft²10 ppm
C-22Inside to outside6”OD x 3.5”ID x 22.25”L2.91 ft²15 - 20 ppm
Prefilter/Coalescer
C-611Inside to outside6”OD x 3.5”ID x 11.25”L3.9 / 1.09 ft²10 ppm
C-614Inside to outside6”OD x 3.5”ID x 14.25”L5.03 / 1.41 ft²10 ppm
C-622Inside to outside6”OD x 3.5”ID x 22.25”L7.73 / 2.16 ft²10 ppm
C-628Inside to outside6”OD x 3.5”ID x 33.25”L8.76 / 2.75 ft²10 ppm
C-633Inside to outside6”OD x 3.5”ID x 33.25”L11.55 / 3.23 ft²10 ppm
C-636Inside to outside6”OD x 3.5”ID x 36”L12.5 / 3.5 ft²10 ppm
C-644Inside to outside6”OD x 3.5”ID x 36”L15.8 / 4.28 ft²10 ppm
C-656Inside to outside6”OD x 3.5”ID x 36”L19.45 / 5.44 ft²10 ppm

Ordering information

TypeModel DimensionsMicron RatingOptionsConfiguration
C – CoalescerDimensional Code005 – 0,5μm
010 – 1,0μm
050 – 5,0μm
100 – 10μm
500 – 50μm
Special ConstructionNo Symbol = DOE
CP – Coalescer with pleated prefilterDimensional Code005 – 0,5μm
010 – 1,0μm
050 – 5,0μm
100 – 10μm
500 – 50μm
TB = Threated Base